Evaluation on the Corrosion of the Three Ni-Cr Alloys with Different Composition
2011

Corrosion Evaluation of Nickel-Chrome Alloys

Sample size: 15 publication 10 minutes Evidence: moderate

Author Information

Author(s): Rao Srinivasa B., Chowdhary Ramesh

Primary Institution: Mamata Dental College and Hospital

Hypothesis

How do different nickel-chrome alloys compare in terms of corrosion resistance?

Conclusion

Dentarum's Remanium CS and Bego's Wiron 99 showed satisfactory corrosion behavior, while Sankin's CB Soft had a higher corrosion rate and lower resistance.

Supporting Evidence

  • Dentarum's Remanium CS had the lowest corrosion rate.
  • Bego's Wiron 99 performed better than Sankin's CB Soft.
  • Sankin's CB Soft had the highest corrosion rate among the tested alloys.

Takeaway

This study looked at how well different dental alloys resist rusting in saliva. Some alloys are better than others at not corroding.

Methodology

The corrosion behavior of three nickel-chrome alloys was evaluated using potentiodynamic polarization method in artificial saliva.

Limitations

The study's findings may not fully represent real-life conditions in the oral environment.

Digital Object Identifier (DOI)

10.1155/2011/397029

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication