Augmentation index assessed by applanation tonometry is elevated in Marfan Syndrome
2007

Augmentation Index in Marfan Syndrome

Sample size: 20 publication Evidence: moderate

Author Information

Author(s): Payne Rupert A, Hilling-Smith Roland C, Webb David J, Maxwell Simon R, Denvir Martin A

Primary Institution: Centre for Cardiovascular Science, University of Edinburgh

Hypothesis

Is the augmentation index (AIx) increased in Marfan syndrome (MFS) and associated with increased aortic root size?

Conclusion

AIx is sensitive to the vascular abnormalities present in MFS and may serve as an adjunct to other measurements.

Supporting Evidence

  • AIx was significantly greater in MFS compared to controls at both radial and carotid sites.
  • Multivariate analysis showed PWV and carotid AIx were positively correlated with aortic root size.
  • GTN caused similar decreases in AIx in both controls and patients.

Takeaway

This study looked at how a measure called augmentation index is higher in people with Marfan syndrome, which might help doctors understand their heart health better.

Methodology

10 MFS patients and 10 healthy controls were studied using applanation tonometry to measure arterial waveforms before and after GTN administration.

Limitations

The study had a small sample size, which may limit the generalizability of the findings.

Participant Demographics

10 MFS patients (7 male), aged 16 to 48 years, matched with 10 healthy controls for age, sex, and height.

Statistical Information

P-Value

0.003 and 0.004 for AIx comparisons

Statistical Significance

p<0.05

Digital Object Identifier (DOI)

10.1186/1749-8090-2-43

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication