Biomarkers of Extracellular Matrix Metabolism (MMP-9 and TIMP-1) and Risk of Stroke, Myocardial Infarction, and Cause-Specific Mortality: Cohort Study
2011

Matrix Biomarkers and Mortality Risk in Elderly Men

Sample size: 1082 publication Evidence: moderate

Author Information

Author(s): Jonas Hansson, Ramachandran S. Vasan, Johan Ärnlöv, Erik Ingelsson, Lars Lind, Anders Larsson, Karl Michaëlsson, Johan Sundström

Primary Institution: Uppsala University, Uppsala, Sweden

Hypothesis

We investigated relations of serum levels of MMP-9 and TIMP-1 to mortality risk from an etiological perspective.

Conclusion

Higher levels of circulating MMP-9 and TIMP-1 are associated with increased mortality risk, particularly cardiovascular mortality and stroke risk.

Supporting Evidence

  • Serum MMP-9 and TIMP-1 levels were associated with risk of all-cause mortality.
  • TIMP-1 levels were mainly related to risks of cardiovascular mortality and stroke.
  • All relations except those of TIMP-1 to stroke risk were attenuated by adjustment for cardiovascular disease risk factors.

Takeaway

This study found that higher amounts of certain proteins in the blood can mean a higher chance of dying, especially from heart problems or strokes.

Methodology

The study used a prospective cohort design, following 1,082 elderly men for up to 18.1 years, measuring serum levels of MMP-9 and TIMP-1 and analyzing their relation to mortality risk.

Potential Biases

Possible pre-analytical errors in measuring biomarkers and misclassification of causes of death.

Limitations

The study only included elderly men, limiting generalizability to women and younger populations.

Participant Demographics

1,082 elderly men, average age 71 years.

Statistical Information

Confidence Interval

95% CI 1.03–1.19 for MMP-9; 95% CI 1.02–1.20 for TIMP-1

Statistical Significance

p<0.05

Digital Object Identifier (DOI)

10.1371/journal.pone.0016185

Want to read the original?

Access the complete publication on the publisher's website