Functional haemodynamic monitoring: the relative merits of SVV, SPV and PPV as measured by the LiDCOrapid in predicting fluid responsiveness in high-risk surgical patients
2011

Functional Haemodynamic Monitoring in High-Risk Surgical Patients

Sample size: 70 publication Evidence: moderate

Author Information

Author(s): Willars C, Dada A, Green D

Primary Institution: Kings College Hospital, London, UK

Hypothesis

Can dynamic measures of cardiac filling predict fluid responsiveness in high-risk surgical patients?

Conclusion

The study found that the Stroke Volume Variation (SVV) was an adequate predictor of fluid responsiveness in high-risk surgical patients.

Supporting Evidence

  • Thirty-two out of 43 valid fluid challenges were positive (74.4%).
  • The correlation coefficients between baseline SVV, SPV and PPV with ΔSVI were 0.27, -0.01 and 0.18 respectively.
  • The AUROCs for SVV, SPV, and PPV were 0.75, 0.587, and 0.67 respectively.
  • The best cut-off value for SVV was 13.5%, with a diagnostic odds ratio of 8.06.

Takeaway

Doctors can use a special measurement called SVV to help decide if patients need more fluids during surgery.

Methodology

The study evaluated the haemodynamic parameters of 70 high-risk patients undergoing major vascular surgery using the LiDCOviewPro.

Limitations

The study was retrospective and only included patients who met specific criteria for fluid challenges.

Participant Demographics

Mean age 71 ± 11.3 years, median ASA 3.

Statistical Information

P-Value

0.08

Confidence Interval

95% CI = 0.57 to 0.93

Statistical Significance

p=0.08

Digital Object Identifier (DOI)

10.1186/cc9486

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication