Intracorneal implantation of a misdirected foldable intraocular lens during phacoemulsification surgery: a case report
2021

Case Report on Misplaced Intraocular Lens During Surgery

Sample size: 1 publication Evidence: low

Author Information

Author(s): Toker Mustafa Ilker, Bozali Erman, Unal Mustafa, Ozec Ayse Vural, Erdogan Haydar

Primary Institution: Ulucanlar Eye Training and Research Hospital, University of Health Sciences, Ankara, Turkey

Hypothesis

Can a misdirected intraocular lens be safely removed and replaced during cataract surgery?

Conclusion

The study highlights the importance of careful incision construction to prevent intraocular lens misdirection during surgery.

Supporting Evidence

  • The patient had a visual acuity of hand movements before surgery.
  • After the lens was removed and replaced, the best-corrected visual acuity improved to 20/40.

Takeaway

A doctor accidentally put a lens in the wrong place during eye surgery, but they were able to fix it and help the patient see better again.

Methodology

The case involved a 59-year-old man who underwent phacoemulsification surgery, where an intraocular lens was mistakenly implanted in the corneal stroma and later removed and replaced.

Limitations

The patient was lost to follow-up, preventing further examination of corneal healing.

Participant Demographics

One 59-year-old male patient.