Hydrocortisone Diffusion Through Synthetic Membrane, Mouse Skin, and Epidermâ„¢ Cultured Skin
2011

Hydrocortisone Diffusion Through Different Membranes

Sample size: 7 publication Evidence: high

Author Information

Author(s): John Mark Christensen, Monica Chang, Le Hang, Pham Loan, Ehab Bendas

Primary Institution: Oregon State University

Hypothesis

The study aims to assess the penetration of hydrocortisone from various topical products through different membranes.

Conclusion

The hydrocortisone gel formulation showed significantly higher penetration rates compared to other topical products.

Supporting Evidence

  • The gel formulation released the highest cumulative amount of hydrocortisone through synthetic membranes.
  • Hydrocortisone diffusion through NHEK was 2.7 times greater from the gel formulation than other topical formulations.
  • Pre-washing the skin significantly increased hydrocortisone diffusion rates.

Takeaway

This study looked at how well hydrocortisone cream can get through skin and other materials, finding that a gel version works best.

Methodology

The study used an Upright Franz Cell to measure hydrocortisone diffusion through synthetic membranes, mouse skin, and cultured human skin.

Limitations

The study had a small sample size, which may affect the reliability of the results.

Statistical Information

P-Value

p<0.01

Confidence Interval

95% CI 1441–1950

Statistical Significance

p<0.01

Digital Object Identifier (DOI)

10.1111/j.1753-5174.2010.00033.x

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication