Breast cancer care compared with clinical Guidelines: an observational study in France
2011

Breast Cancer Care and Compliance with Guidelines in France

Sample size: 926 publication 10 minutes Evidence: moderate

Author Information

Author(s): Lebeau Marie, Mathoulin-Pélissier Simone, Bellera Carine, Tunon-de-Lara Christine, Daban Alain, Lipinski Francis, Jaubert Dominique, Ingrand Pierre, Migeot Virginie

Primary Institution: CHU de Poitiers, France

Hypothesis

What factors are associated with non-compliance to clinical practice guidelines in breast cancer care?

Conclusion

The study identifies significant factors contributing to non-compliance in breast cancer management, suggesting areas for quality improvement.

Supporting Evidence

  • Older age and region were associated with non-compliance in treatment decisions.
  • Non-compliance was highest for radiotherapy, particularly due to delays.
  • Patients with positive lymph nodes had a higher risk of non-compliance.

Takeaway

This study looked at how well doctors follow guidelines for treating breast cancer and found that many patients didn't get the recommended care.

Methodology

The study involved collecting medical data from patient records across 99 hospitals in two French regions, focusing on compliance with 20 clinical practice guidelines.

Potential Biases

Variability in compliance may be influenced by local cancer unit practices and patient demographics.

Limitations

Potential selection bias due to non-participation of some eligible patients and variability in hospital practices.

Participant Demographics

{"mean_age":58.5,"age_distribution":{"<50":27,"50-69":51,">=70":22},"educational_level":{"less_than_baccalaureate":71,"baccalaureate_or_higher":29},"menopausal_status":{"postmenopausal":67,"premenopausal":33},"nodal_status":{"negative":63,"positive":37}}

Statistical Information

Confidence Interval

{"age":"95% CI: 1.3-3.6","region":"95% CI: 1.2-7.4","peritumoural_vascular_invasion":"95% CI: 1.01-2.3","grade_III":"95% CI: 1.4-6.2","lymph_nodes":"95% CI: 1.2-3.3"}

Statistical Significance

p<0.05

Digital Object Identifier (DOI)

10.1186/1471-2458-11-45

Want to read the original?

Access the complete publication on the publisher's website