All that glisters is not gold: a comparison of electronic monitoring versus filled prescriptions – an observational study
2006

Comparing Electronic Monitoring and Refill Compliance in Hypertension

Sample size: 161 publication Evidence: moderate

Author Information

Author(s): Gwenn EC Wetzels, Patricia J Nelemans, Jan SAG Schouten, Boris LG van Wijk, Martin H Prins

Primary Institution: Department of Epidemiology, University of Maastricht

Hypothesis

Is electronic monitoring a more accurate measure of patient compliance with antihypertensive medication compared to refill compliance?

Conclusion

Electronic monitoring may not provide valid compliance data if patients are aware they are being monitored.

Supporting Evidence

  • Electronic monitoring showed high compliance rates, while refill compliance indicated a higher percentage of poor compliers.
  • Cohen's kappa coefficient was 0.005, indicating poor agreement between the two compliance measures.
  • The study included 161 patients with hypertension and inadequate blood pressure control.

Takeaway

This study looked at how well patients follow their blood pressure medication. It found that just because patients get their prescriptions filled doesn't mean they actually take their medicine.

Methodology

The study compared patient compliance using electronic monitoring and refill compliance in 161 hypertensive patients over a period of 12 months.

Potential Biases

Patients being aware of the monitoring may have influenced their compliance behavior.

Limitations

The short duration of electronic monitoring may not provide stable estimates of compliance.

Participant Demographics

{"age":{"≤ 55":21,"56–65":44,"66–75":26,"≥ 75":8},"gender":{"male":48,"female":52},"education":{"low":22,"middle":32,"high":33,"very high":11},"employment":{"yes":31,"no":68}}

Statistical Information

P-Value

p < 0.001

Confidence Interval

95% CI: [-0.18-0.15]

Statistical Significance

p < 0.001

Digital Object Identifier (DOI)

10.1186/1472-6963-6-8

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication