Understanding Green Discoloration in Serum and Plasma Samples
Author Information
Author(s): Iva Friščić, Sonja Perkov, Mirjana Mariana Kardum Paro
Primary Institution: Merkur University Hospital, Zagreb, Croatia
Hypothesis
What is the impact of green discoloration in serum and citrate plasma samples on laboratory test results?
Conclusion
The green discoloration in serum and citrate plasma samples has minimal impact on the reliability of laboratory test results.
Supporting Evidence
- The green discoloration was caused by the sterile dye Patent Blue V used during surgery.
- Laboratory tests showed minimal interference from the green discoloration on routine clinical chemistry analyses.
- Sample dilution effectively reduced the positive interference observed in the lipemia index.
Takeaway
Sometimes blood samples can turn green, but this doesn't usually mess up the test results. It's important to check and make sure the tests are still accurate.
Methodology
The study involved analyzing blood samples from a male adult patient who underwent a multivisceral organ transplant, focusing on the effects of green discoloration on various laboratory tests.
Potential Biases
Potential for bias due to the unique circumstances of the case and the specific dye used.
Limitations
The study is based on a single case report, which may limit the generalizability of the findings.
Participant Demographics
A male adult patient who underwent a multivisceral organ transplant.
Digital Object Identifier (DOI)
Want to read the original?
Access the complete publication on the publisher's website