Understanding green discoloration in serum and citrate plasma samples: a case report
2023

Understanding Green Discoloration in Serum and Plasma Samples

Sample size: 1 publication Evidence: low

Author Information

Author(s): Iva Friščić, Sonja Perkov, Mirjana Mariana Kardum Paro

Primary Institution: Merkur University Hospital, Zagreb, Croatia

Hypothesis

What is the impact of green discoloration in serum and citrate plasma samples on laboratory test results?

Conclusion

The green discoloration in serum and citrate plasma samples has minimal impact on the reliability of laboratory test results.

Supporting Evidence

  • The green discoloration was caused by the sterile dye Patent Blue V used during surgery.
  • Laboratory tests showed minimal interference from the green discoloration on routine clinical chemistry analyses.
  • Sample dilution effectively reduced the positive interference observed in the lipemia index.

Takeaway

Sometimes blood samples can turn green, but this doesn't usually mess up the test results. It's important to check and make sure the tests are still accurate.

Methodology

The study involved analyzing blood samples from a male adult patient who underwent a multivisceral organ transplant, focusing on the effects of green discoloration on various laboratory tests.

Potential Biases

Potential for bias due to the unique circumstances of the case and the specific dye used.

Limitations

The study is based on a single case report, which may limit the generalizability of the findings.

Participant Demographics

A male adult patient who underwent a multivisceral organ transplant.