Ischemia monitoring in off-pump coronary artery bypass surgery using intravascular near-infrared spectroscopy
2006

Monitoring Heart Ischemia During Bypass Surgery

Sample size: 15 publication Evidence: moderate

Author Information

Author(s): Bernet Franziska H, Reineke David, Zerkowski Hans-Reinhard, Baykut Doan

Primary Institution: University Hospital Basel, Switzerland

Hypothesis

Can intravascular near-infrared spectroscopy reliably monitor ischemic events during off-pump coronary artery bypass surgery?

Conclusion

Intravascular near-infrared spectroscopy can be used for online monitoring of ischemia during off-pump coronary artery bypass surgery, but further evaluation is needed.

Supporting Evidence

  • The mean number of grafts per patient was 3.1.
  • No intraoperative myocardial ischemia was evident in any patient.
  • Significant changes in ischemic markers were observed at the end of revascularization.

Takeaway

Doctors used a special light to check if the heart was getting enough oxygen during surgery, and it seemed to work well, but they need to test it more.

Methodology

Fifteen patients underwent off-pump coronary artery bypass surgery with intravascular near-infrared spectroscopy monitoring of coronary venous blood.

Potential Biases

The study design may not account for variations in patient conditions that could affect results.

Limitations

The study involved a small number of low-risk patients, limiting the generalizability of the findings.

Participant Demographics

13 male and 2 female patients with a mean age of 61.3 years.

Statistical Information

P-Value

p < 0.001 for troponin I, p = 0.003 for CK-MB, p = 0.001 for myoglobin

Statistical Significance

p<0.05

Digital Object Identifier (DOI)

10.1186/1749-8090-1-12