Measuring Running Parameters with GPS and Infrared Mat
Author Information
Author(s): Provot Thomas, Millot Benjamin, Hazotte Eline, Rousseau Thomas, Slawinski Jean
Primary Institution: EPF–Engineering School
Hypothesis
A GPS unit with an IMU will accurately measure spatiotemporal parameters during sprints.
Conclusion
The GPS-IMU system accurately measured spatiotemporal parameters across different running velocities, demonstrating low relative errors and high precision.
Supporting Evidence
- The GPS-IMU system showed a very large agreement with the reference system for step frequency (r2 = 0.92).
- The step length measured by the GPS unit had a very large correlation with the reference system (r2 = 0.91).
- The step velocity computed using the GPS unit was very close to that measured with the infrared mat (r2 = 0.99).
- The average relative errors for step frequency, step length, and step velocity were less than 5%.
- The study demonstrated that GPS-IMU systems can provide comprehensive spatiotemporal data for training and competition.
Takeaway
This study shows that a special GPS device can help coaches measure how fast and far runners step, making it easier to improve their performance.
Methodology
Five experienced male runners performed six 40 m sprints at three different speeds while using a GPS-IMU system and an optical system as a reference.
Potential Biases
Potential inaccuracies in measuring the first steps due to the GPS unit's position.
Limitations
The study's participants were not high-level sprinters, which may have influenced the results.
Participant Demographics
Five male recreational runners, average weight 71.63 kg and height 182.2 cm.