CHA2DS2 ‐VASc score and prior oral anticoagulant use on endovascular treatment for acute ischemic stroke
2024

Impact of CHA2DS2-VASc Score and Anticoagulant Use on Stroke Treatment Outcomes

Sample size: 6984 publication 10 minutes Evidence: high

Author Information

Author(s): Y. Imaoka, R. Nice, S. Ogata, H. Imamura, Y. Kaku, K. Arimura, S. Watanabe, E. Kiyoshige, K. Nishimura, S. Kobashi, M. Ihara, K. Kamiyama, M. Morimoto, T. Ohta, H. Endo, Y. Matsumaru, N. Sakai, T. Kitazono, S. Fujimoto, K. Ogasawara, K. Iihara

Primary Institution: National Cerebral and Cardiovascular Center, Osaka, Japan

Hypothesis

The study evaluates the effect of CHA2DS2-VASc score and prior use of oral anticoagulants on endovascular treatment outcomes in patients with acute ischemic stroke and atrial fibrillation.

Conclusion

Prior use of direct oral anticoagulants improves successful and complete reperfusion rates in high-risk patients, while warfarin use increases the risk of complications.

Supporting Evidence

  • Higher CHA2DS2-VASc scores were linked to worse outcomes after treatment.
  • Prior DOAC use improved successful reperfusion rates in high-risk patients.
  • Warfarin use was associated with increased risk of symptomatic intracerebral hemorrhage.

Takeaway

This study found that using certain blood thinners before a stroke can help patients recover better after treatment, but using another type can lead to more problems.

Methodology

The study analyzed data from 6984 patients with atrial fibrillation who received endovascular treatment across 353 centers in Japan, focusing on outcomes related to CHA2DS2-VASc scores and prior anticoagulant use.

Potential Biases

Potential selection bias from participating hospitals and confounding factors related to patient backgrounds.

Limitations

The study's findings may not be generalizable to other populations, and it was retrospective, which could introduce bias.

Participant Demographics

Median age was 80 years, with 48.5% female participants.

Statistical Information

P-Value

p=0.003

Confidence Interval

1.00–1.61

Statistical Significance

p<0.05

Digital Object Identifier (DOI)