Reproducibility of different screening classifications in ultrasonography of the newborn hip
2010

Reproducibility of Hip Ultrasound Screening in Newborns

Sample size: 207 publication Evidence: moderate

Author Information

Author(s): Peterlein Christian D, Schüttler Karl F, Lakemeier Stefan, Timmesfeld Nina, Görg Christian, Fuchs-Winkelmann Susanne, Schofer Markus D

Primary Institution: University Hospital Giessen and Marburg

Hypothesis

The study aims to examine the degree of concordance of two objective classifications of hip morphology and subjective parameters by three investigators with different levels of experience.

Conclusion

The study demonstrates that adequate inter- and intra-observer reliability can be obtained for both objective and descriptive parameters in hip ultrasound, regardless of the investigator's experience.

Supporting Evidence

  • The mean α-angle was 64.9° with a range of 46.3° - 75.2°.
  • The mean β-angle was 61.4° with a range of 50.5° - 91.3°.
  • The mean femoral head coverage (FHC) was 61.4% with a range of 49.4% - 90.8%.
  • Intra-observer reproducibility was high for subjective parameters with kappa-coefficients of 0.97 and 1.0.

Takeaway

Doctors used ultrasound to check newborns' hips, and they found that even less experienced doctors could get good results.

Methodology

Ultrasound measurements were performed on 207 newborns by three investigators with varying experience, assessing angles and coverage of the hip.

Limitations

The study had a small number of dysplastic hips, which limits the reliability of the data for abnormal hips.

Participant Demographics

101 boys and 106 girls, average age of 2.64 days.

Statistical Information

P-Value

p < 10-7

Statistical Significance

p < 10-7

Digital Object Identifier (DOI)

10.1186/1471-2431-10-98