Ultrasound-guided large-core needle biopsies of breast lesions: analysis of 962 cases to determine the number of samples for reliable tumour classification
2005

Breast Biopsy Study: How Many Samples Are Enough?

Sample size: 962 publication Evidence: high

Author Information

Author(s): G Sauer, H Deissler, K Strunz, G Helms, E Remmel, K Koretz, R Terinde, R Kreienberg

Primary Institution: University of Ulm Medical School

Hypothesis

How many large-core needle biopsies are needed for reliable tumor classification of breast lesions?

Conclusion

Three 3D ultrasound-guided core samples are sufficient for a reliable histological assessment of breast lesions.

Supporting Evidence

  • 98.2% sensitivity for diagnosing breast malignancies with three cores.
  • Only 3.9% false-negative rate in identifying malignancies.
  • 75.9% of cases required only two biopsies for a clear diagnosis.

Takeaway

Doctors can use just three needle samples to check for breast cancer instead of more, making the process easier for patients.

Methodology

The study analyzed 962 breast lesions using 3D ultrasound-guided large-core needle biopsies over 28 months.

Potential Biases

Potential bias due to the single-institution study design and operator experience.

Limitations

The study was conducted at a single institution, which may limit generalizability.

Participant Demographics

906 patients with breast lesions, both palpable and nonpalpable.

Statistical Information

P-Value

0.001

Statistical Significance

p=0.001

Digital Object Identifier (DOI)

10.1038/sj.bjc.6602303

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication