Reducing Retinopathy of Prematurity in Preterm Infants with Pulse Oximetry
Author Information
Author(s): Castillo Armando, Deulofeut Richard, Critz Ann, Sola Augusto
Primary Institution: Emory University
Hypothesis
The relative risk reduction in severe retinopathy of prematurity is associated with the saturation technology utilized in neonatal intensive care units.
Conclusion
A change in clinical practice and the use of pulse oximetry with Masimo SET technology significantly reduced severe ROP and the need for laser therapy in preterm infants.
Supporting Evidence
- Severe ROP decreased from 12% to 5% at Centre B after implementing SET technology.
- Need for laser treatment decreased from 5% to 3% at Centre B after the change to SET technology.
- At Centre A, severe ROP decreased from 13% to 6% after changing to SET technology.
Takeaway
Using better pulse oximetry technology can help prevent serious eye problems in premature babies.
Methodology
Inborn infants <1250 g who had eye exams were compared at two centres over three periods with different SpO2 targets and pulse oximetry technologies.
Potential Biases
The study design may not definitively isolate the pulse oximetry technology as the only factor contributing to the decrease in ROP.
Limitations
This was not a randomized controlled trial, and different bedside nurses and respiratory therapists were involved at the two centres.
Participant Demographics
Inborn infants with birth weight <1250 g, with similar birth weight and gestational age across periods.
Statistical Information
P-Value