Diagnostic Accuracy of Lipid Transfer Proteins in Food Allergy
Author Information
Author(s): Bellia Chiara, Sardina Davide Stefano, Scazzone Concetta, Lio Domenico, Scola Letizia, Uasuf Carina Gabriela
Primary Institution: University of Palermo
Hypothesis
What is the diagnostic accuracy of molecular-based LTPs allergens serological tests for the diagnosis of food allergies?
Conclusion
The LTP-specific IgE assay has very low sensitivity and acceptable specificity, making it suitable for confirming food allergy when food challenge is not practicable.
Supporting Evidence
- The sensitivity of Ara h 9 for peanut allergy diagnosis ranged from 6 to 61%.
- The specificity of Ara h 9 ranged from 57 to 100%.
- The sensitivity of Cor a 8 for hazelnut allergy diagnosis ranged from 11 to 43%.
- The specificity of Cor a 8 ranged from 59 to 94%.
- Fifteen articles, including 2395 individuals, were included in the review.
Takeaway
This study looked at how well a blood test can tell if someone is allergic to certain foods. It found that while the test can be helpful, it doesn't always work perfectly.
Methodology
A systematic review of cohort, prospective, or retrospective cross-sectional studies evaluating the diagnostic accuracy of LTPs serum sIgE for food allergies.
Potential Biases
High risk of bias for the reference standard due to the use of open food challenges instead of double-blind placebo-controlled challenges.
Limitations
High risk of bias in many studies due to the use of different challenge protocols and varying proportions of patients undergoing the reference standard.
Participant Demographics
Most participants were pediatric, with only three studies including adults aged 18 to 46 years.
Digital Object Identifier (DOI)
Want to read the original?
Access the complete publication on the publisher's website