Fluorescent Copolymers for Detecting Picric Acid
Author Information
Author(s): Lin Hong-Jia, Tseng Po-Hsiang, Wu Wen-Chung
Primary Institution: Department of Chemical Engineering, National Cheng Kung University, Tainan, Taiwan
Hypothesis
Can fluorescent copolymers be effectively used to detect picric acid?
Conclusion
The study found that the PNNP sensor has higher sensitivity for detecting picric acid compared to the PNNS sensor due to its aggregation-induced emission properties.
Supporting Evidence
- The average diameters of PNNS and PNNP nanofibers were 179 ± 28 nm and 235 ± 143 nm, respectively.
- The Stern-Volmer constant (Ksv) values for PNNS and PNNP nanofibers were 0.012 μΜ−1 and 0.119 μΜ−1, respectively.
- Both nanofiber films can be reused after washing with pure methanol or deionized water.
Takeaway
Scientists created special materials that can glow and help find dangerous chemicals like picric acid. One type of material worked better than the other.
Methodology
The researchers synthesized two types of fluorescent copolymers and tested their ability to detect picric acid using fluorescence quenching.
Limitations
The sensitivity of the PNNS sensor was lower compared to other sensors reported in the literature.
Digital Object Identifier (DOI)