Characterization of the effect of sample quality on high density oligonucleotide microarray data using progressively degraded rat liver RNA
2007

Impact of RNA Quality on Microarray Data

Sample size: 32 publication Evidence: moderate

Author Information

Author(s): Karol L. Thompson, Scott P. Pine, Barry A. Rosenzweig, Yaron Turpaz, Jacques Retief

Primary Institution: Center for Drug Evaluation and Research, US Food and Drug Administration

Hypothesis

How does RNA quality affect microarray assay performance?

Conclusion

Moderate RNA degradation is tolerated by microarrays, but a threshold exists beyond which specificity and sensitivity decrease.

Supporting Evidence

  • RNA integrity affects microarray assay performance.
  • Samples with RNA integrity numbers less than or equal to 7 showed increased false positives.
  • Moderate RNA degradation is tolerated by microarrays with 3'-biased probe selection designs.
  • Incubation at 37°C had little effect on RNA integrity but induced changes in gene expression.
  • Thawing of tissue led to rapid loss of RNA integrity.

Takeaway

If the RNA used in tests is not good quality, it can lead to wrong results. This study shows how important it is to check RNA quality before using it in experiments.

Methodology

The study used rat liver RNA samples with varying RNA integrity, analyzed on Affymetrix GeneChip arrays to assess the impact of RNA quality on microarray performance.

Potential Biases

Potential biases may arise from the handling and processing of RNA samples, which could affect the results.

Limitations

The study primarily focused on rat liver samples, which may not generalize to other tissues or species.

Participant Demographics

Male Sprague Dawley rats were used in the study.

Statistical Information

P-Value

p<0.05

Statistical Significance

p<0.05

Digital Object Identifier (DOI)

10.1186/1472-6750-7-57

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication