Stepwise complexometric determination of aluminium, titanium and iron concentrations in silica sand and allied materials
2007

Measuring Aluminium, Titanium, and Iron in Silica Sand

Sample size: 5 publication Evidence: moderate

Author Information

Author(s): Kayal Nijhuma, Singh Nahar

Primary Institution: Central Glass and Ceramic Research Institute, Kolkata, India

Hypothesis

This study aimed at measuring the quantities of Al, Ti and Fe in silica sand and allied materials employing a complexometric method.

Conclusion

The study shows that there is good agreement between the proposed and existing methods for determining Al, Ti, and Fe in silica sand.

Supporting Evidence

  • The method was validated by analyzing NIST Standard Reference Materials.
  • The standard deviations of the measurements were found to be less than 1.5%.
  • The proposed method is simpler and faster compared to existing methods.

Takeaway

The researchers found a simple way to measure metals in sand without needing complicated tools, and it works well.

Methodology

The method involves complexation of Al, Ti, and Fe with EDTA, followed by selective de-complexation and back titration.

Limitations

The method is not suitable for higher concentrations of Ti and Fe (above 6%) and shows more uncertainty at lower concentrations (less than 0.01%).