Screening for low bone mass with quantitative ultrasonography in a community without dual-energy X-ray absorptiometry: population-based survey
2006

Screening for Low Bone Mass in a Community Without DXA

Sample size: 6493 publication Evidence: moderate

Author Information

Author(s): Yang Nan-Ping, Jen Ian, Chuang Shao-Yuan, Chen Shui-Hu, Chou Pesus

Primary Institution: National Yang-Ming University

Hypothesis

Can quantitative ultrasonography (QUS) effectively screen for low bone mass in a community lacking access to dual-energy X-ray absorptiometry (DXA)?

Conclusion

Age-related decreases in calcaneal ultrasonometry, which reflected the prevalence of low bone mass, were more obvious in women than in men.

Supporting Evidence

  • The correlation coefficient between two QUS machines was 0.90.
  • Calcaneal BUA was significantly correlated with BMD in the femoral neck (r = 0.67) and lumbar spine (r = 0.59).
  • Annual losses of calcaneal BUA were 0.83% for women and 0.27% for men.

Takeaway

This study looked at how well a special ultrasound can check for weak bones in a place where the usual bone scan isn't available, finding that older women are more affected.

Methodology

A cross-sectional, community-based study where 6493 residents underwent ultrasonographic measurements and completed a questionnaire.

Potential Biases

Potential bias due to exclusion of military personnel and those with chronic disorders.

Limitations

The study could not calculate the true response rate due to the transient population in Kinmen and lacked normative data for DXA.

Participant Demographics

2792 men (43.0%) and 3701 women (57.0%) aged 40 years or older.

Statistical Information

P-Value

p<0.001

Confidence Interval

95% confidence interval 0.85–0.94

Statistical Significance

p<0.001

Digital Object Identifier (DOI)

10.1186/1471-2474-7-24

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication