Corneal reshaping: an experiment with a type I collagen-based vitrigel for remodeling porcine corneas
2022

Corneal Reshaping with a New Collagen-Based Implant

Sample size: 12 publication Evidence: moderate

Author Information

Author(s): Marquezan Maria Carolina, de Freitas Denise, Majumdar Shoumyo, Wang Xiaokun, Elisseeff Jennifer, Guyton David L., Bower Kraig Scot, Skurski Zachary P., Chalita Maria Regina, Belfort Jr Rubens, Jun Albert S.

Primary Institution: Wilmer Eye Institute, Johns Hopkins University School of Medicine

Hypothesis

Can a new type I collagen-based vitrigel implant reshape porcine corneas?

Conclusion

The study found that the novel biomaterial implant could reshape the cornea in an ex vivo model, leading to flattening.

Supporting Evidence

  • Corneal tomography showed a trend for decreased mean keratometry in all treatment groups.
  • Optical coherence tomography showed corneas with implants visibly flattening.
  • The control group did not show qualitative changes in corneal shape.

Takeaway

Scientists tested a new gel to see if it could change the shape of pig eyes, and it worked to make them flatter.

Methodology

An ex vivo porcine eye model was used with a type I collagen-based vitrigel implant inserted into stromal pockets and evaluated using optical coherence tomography and corneal tomography.

Limitations

The study had a small sample size and used postmortem eyes, which presented technical challenges.

Participant Demographics

Porcine eyes were used in the study.

Statistical Information

P-Value

<0.05

Statistical Significance

p<0.05

Digital Object Identifier (DOI)

10.5935/0004-2749.2022-0128

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication