Methods for improving the thermal performance of thermal bridges of lightweight steel-framed buildings
2024

Improving Thermal Performance of Lightweight Steel-Framed Buildings

publication Evidence: moderate

Author Information

Author(s): Qi Xuejun, Tan Yuxin, Tan Jinsheng, Li Xiaohong

Primary Institution: School of Architecture and Civil Engineering, Xihua University, Chengdu, China

Hypothesis

How can the thermal performance of thermal bridges in lightweight steel-framed buildings be improved?

Conclusion

The study found that increasing the thickness of insulation materials can significantly reduce thermal bridge effects and meet design standards for energy efficiency.

Supporting Evidence

  • When the thickness of rock wool insulation is greater than 75 mm, the thermal bridge coefficient meets the design standard.
  • Using polyurethane insulation instead of rock wool can also meet the design standard with a thickness greater than 65 mm.
  • The thermal bridge of the cornice can meet the standard with a polyurethane layer thicker than 20 mm.

Takeaway

This study shows that making walls thicker with special materials can help keep buildings warm and save energy.

Methodology

Infrared technology was used to measure temperatures, and THERM software was used for numerical simulations of thermal bridges.

Limitations

The study focuses on specific thermal bridge types and may not cover all scenarios in different building designs.

Digital Object Identifier (DOI)

10.1371/journal.pone.0314634

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication