Improving Thermal Performance of Lightweight Steel-Framed Buildings
Author Information
Author(s): Qi Xuejun, Tan Yuxin, Tan Jinsheng, Li Xiaohong
Primary Institution: School of Architecture and Civil Engineering, Xihua University, Chengdu, China
Hypothesis
How can the thermal performance of thermal bridges in lightweight steel-framed buildings be improved?
Conclusion
The study found that increasing the thickness of insulation materials can significantly reduce thermal bridge effects and meet design standards for energy efficiency.
Supporting Evidence
- When the thickness of rock wool insulation is greater than 75 mm, the thermal bridge coefficient meets the design standard.
- Using polyurethane insulation instead of rock wool can also meet the design standard with a thickness greater than 65 mm.
- The thermal bridge of the cornice can meet the standard with a polyurethane layer thicker than 20 mm.
Takeaway
This study shows that making walls thicker with special materials can help keep buildings warm and save energy.
Methodology
Infrared technology was used to measure temperatures, and THERM software was used for numerical simulations of thermal bridges.
Limitations
The study focuses on specific thermal bridge types and may not cover all scenarios in different building designs.
Digital Object Identifier (DOI)
Want to read the original?
Access the complete publication on the publisher's website