Evaluation of the Wear of Ni 200 Alloy After Long-Term Carbon Capture in Molten Salts Process
2024

Wear Evaluation of Nickel 200 Alloy in Carbon Capture Process

Sample size: 1 publication 10 minutes Evidence: moderate

Author Information

Author(s): Palimąka Piotr, Pietrzyk Stanisław, Balcerzak Maciej, Żaba Krzysztof, Leszczyńska-Madej Beata, Jaskowska-Lemańska Justyna

Primary Institution: AGH University of Krakow

Hypothesis

The study evaluates the wear of Nickel 200 Alloy components used in a carbon capture device after long-term exposure to molten salts.

Conclusion

The study found significant wear on the lance component, with a wear rate of approximately 3.9 mm/year due to prolonged contact with molten salts.

Supporting Evidence

  • The lance experienced a wear rate of 3.9 mm/year in contact with molten salts.
  • Microscopic analysis revealed intergranular corrosion on the lance.
  • The study utilized advanced imaging techniques like X-ray and computed tomography to assess wear.

Takeaway

This study looked at how a special metal used in a carbon capture machine got worn down after being in hot, salty liquid for a long time.

Methodology

The research involved testing the wear of Nickel 200 Alloy components in a carbon capture device under high temperatures and corrosive conditions for 800 hours.

Limitations

The study primarily focused on a single type of alloy and its performance under specific conditions, which may not represent all scenarios in carbon capture technology.

Digital Object Identifier (DOI)

10.3390/ma17246302

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication