Measuring Gum Thickness in Orthodontic Patients
Author Information
Author(s): Kloukos Dimitrios, Kakali Lydia, Koukos George, Sculean Anton, Stavropoulos Andreas, Katsaros Christos
Primary Institution: Department of Orthodontics and Dentofacial Orthopedics, University of Bern, Switzerland
Hypothesis
To compare the effectiveness of ultrasound and cone-beam CT in measuring gingival thickness in orthodontic patients.
Conclusion
CBCT imaging for gingival thickness assessment is as reliable as ultrasound, but consistently yields higher values.
Supporting Evidence
- CBCT measurements were consistently higher than USD measurements.
- No statistically significant difference was noted between repeated CBCT measurements at the right central incisor.
- The difference in measurements was small and not clinically significant.
Takeaway
This study looked at how thick people's gums are before braces using two different machines. One machine showed thicker gums than the other, but both were good at measuring.
Methodology
Gingival thickness was measured using ultrasound and cone-beam CT in 40 orthodontic patients just before bracket placement.
Potential Biases
Potential measurement errors due to the subjective nature of the methods used.
Limitations
The study did not account for variations in dental arch crowding or tooth inclination that could affect measurements.
Participant Demographics
40 Caucasian orthodontic patients, aged 16 and older.
Statistical Information
P-Value
0.014
Confidence Interval
95% CI = 0.01, 0.11
Statistical Significance
p<0.05