Research
2024

Home-Made Lateral Flow Test Strip Versus POC-CCA Assay for Detection of Active Schistosomiasis in Egypt

Sample size: 80 publication Evidence: high

Author Information

Author(s): Kamel Manal, Salah Faten, Demerdash Zeinab, Maher Sara, El-Baz Hanan, Zakaria Nahla, Abu-Shady Rania, Saad Amany, Hassan Salwa, Aziz Doaa Abdel

Primary Institution: Theodor Bilharz Research Institute

Hypothesis

The study aims to compare the effectiveness of a gold nanoparticle-based lateral flow test strip with a commercially available point-of-care assay for diagnosing active Schistosoma mansoni.

Conclusion

The developed lateral flow test strip is more reliable and effective than the commercially available kits for diagnosing schistosomiasis.

Supporting Evidence

  • The LFTS showed a sensitivity of 96.7% and specificity of 95%.
  • The kappa value for the LFTS was 0.902, indicating almost perfect agreement with the KK technique.
  • Only 2 out of 60 cases were negative using the LFTS compared to 9 with the POC-CCA.

Takeaway

Researchers created a new test to quickly find out if someone has schistosomiasis, and it works better than the old tests.

Methodology

The study involved collecting urine samples from patients, developing monoclonal antibodies, and comparing the new test with a standard reference method.

Limitations

Further assessments on a larger scale are needed before the test can be widely used.

Participant Demographics

Patients aged 12 to 30 years from endemic areas in Egypt.

Statistical Information

P-Value

p<0.000

Confidence Interval

0.991-1.000

Statistical Significance

p<0.000

Digital Object Identifier (DOI)

10.1007/s11686-024-00917-9

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication