Hypothesis

There is no gold standard for assessing left ventricular asynchrony for cardiac resynchronization therapy (CRT).

Conclusion

Various echocardiographic methods have shown asynchronous left ventricular contraction in heart failure patients and resynchronized contraction during CRT.

Supporting Evidence

  • Surface ECG is a widely used marker for left ventricular asynchrony but may not be sufficient.
  • Echocardiographic methods have shown asynchronous left ventricular contraction in heart failure patients.
  • Mechanical asynchrony can be assessed using various imaging techniques, including MRI and scintigraphy.
  • Different studies have shown varying degrees of success in predicting clinical response to CRT.

Takeaway

Doctors are trying to find the best ways to see if a heart is beating out of sync, which can help them decide if a special treatment called CRT will work.

Methodology

This review presents an overview of techniques for identifying left ventricular intra- and interventricular asynchrony, including surface ECG, echocardiography, and other imaging methods.

Limitations

There is still no gold standard for assessment of LV asynchrony for CRT.