A Novel Metered Dose Transdermal Spray Formulation for Oxybutynin
2008

New Transdermal Spray for Oxybutynin

Sample size: 6 publication Evidence: moderate

Author Information

Author(s): Bakshi A., Bajaj A., Malhotra G., Madan M., Amrutiya N.

Primary Institution: C. U. Shah College of Pharmacy, SNDT Women's University, Mumbai, India

Hypothesis

Can a metered dose transdermal spray formulation effectively deliver oxybutynin?

Conclusion

The metered dose transdermal spray formulation for oxybutynin shows promising results for effective drug delivery.

Supporting Evidence

  • The developed formulation showed a drug release of almost 50% over 24 hours.
  • Stability studies indicated that the formulations were stable under ICH guidelines.
  • Skin irritation studies showed no erythema or edema in rabbits.

Takeaway

This study created a new spray that helps deliver a medicine called oxybutynin through the skin, which might be easier and better for patients.

Methodology

The study involved developing a metered dose transdermal spray and conducting in vitro characterization, stability, and skin irritation studies using rabbit skin.

Limitations

Results need confirmation through pharmacokinetic studies.

Participant Demographics

Rabbit ear skin was used as the model for in vitro studies.

Statistical Information

P-Value

p≤0.05

Statistical Significance

p≤0.05

Digital Object Identifier (DOI)

10.4103/0250-474X.49094

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication