Factors associated with increased radiation exposure in the fixation of proximal femoral fractures
2025

Factors Affecting Radiation Exposure in Hip Fracture Surgery

Sample size: 184 publication 10 minutes Evidence: moderate

Author Information

Author(s): Amr Elbahi, Thomas O, Dungey M, Randall C, Menon DK

Primary Institution: Dartford and Gravesham NHS Trust, UK

Hypothesis

What factors are associated with increased radiation exposure during the fixation of proximal femoral fractures?

Conclusion

Increased radiation exposure during hip fracture fixation is linked to complex fractures, certain fracture types, specific implants, and the use of additional implants.

Supporting Evidence

  • Higher radiation exposure was associated with complex fractures and certain implant types.
  • Surgeon experience did not significantly reduce radiation exposure.
  • Using additional implants increased radiation exposure during surgery.

Takeaway

This study found that fixing complicated hip fractures uses more radiation, and using certain tools can also increase the amount of radiation doctors and patients get.

Methodology

The study reviewed 369 hip fractures over a year, analyzing factors like fracture type, implants used, and surgeon experience in relation to radiation exposure.

Potential Biases

Potential bias due to retrospective data collection and missing data on some cases.

Limitations

The study had a relatively small cohort and incomplete documentation for some cases.

Participant Demographics

Mean age of participants was 83.5 years, with 69% being female.

Statistical Information

P-Value

p = 0.001

Statistical Significance

p<0.001

Digital Object Identifier (DOI)

10.1308/rcsann.2023.0092

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication