Estimation of Duloxetine Hydrochloride in Pharmaceutical Formulations by RP-HPLC Method
2008
Measuring Duloxetine in Medicines
Sample size: 20
publication
Evidence: high
Author Information
Author(s): Patel Sejal K., Patel N. J., Patel K. M., Patel P. U., Patel B. H. S. K.
Primary Institution: Patel College of Pharmaceutical Education and Research, Ganpat University
Hypothesis
A new method for estimating duloxetine hydrochloride in pharmaceutical formulations is proposed.
Conclusion
The developed RP-HPLC method is simple, precise, and accurate for estimating duloxetine HCl in marketed formulations.
Supporting Evidence
- The method was validated for linearity, accuracy, and precision.
- The limit of detection was found to be 0.10 μg/ml.
- The limit of quantification was found to be 0.25 μg/ml.
- The calibration range was established as 0.25-4 μg/ml.
- The method showed good linearity with a correlation coefficient of 0.9994.
Takeaway
This study created a new way to measure a medicine called duloxetine in pills, making it easier and more accurate.
Methodology
The study used reverse phase high performance liquid chromatography (RP-HPLC) to estimate duloxetine HCl in capsule formulations.