MR Angiography of Collateral Arteries in a Hind Limb Ischemia Model: Comparison between Blood Pool Agent Gadomer and Small Contrast Agent Gd-DTPA
2011

Comparing Gadomer and Gd-DTPA for Imaging Small Collateral Arteries

Sample size: 10 publication Evidence: moderate

Author Information

Author(s): Karolien Jaspers, Bas Versluis, Tim Leiner, Petra Dijkstra, Marlies Oostendorp, Jolanda M. van Golde, Mark J. Post, Walter H. Backes

Primary Institution: Cardiovascular Research Institute Maastricht, Maastricht, The Netherlands

Hypothesis

The study aims to compare the blood pool agent Gadomer with a small contrast agent for the visualization of ultra-small collateral arteries using MR angiography.

Conclusion

Gadomer improved vessel visibility compared to Gd-DTPA, making it a promising option for non-invasive imaging of small collateral arteries.

Supporting Evidence

  • Gadomer provided significantly higher contrast-to-noise ratios in both femoral and collateral arteries compared to Gd-DTPA.
  • The number of collaterals identified was comparable between Gadomer and Gd-DTPA, mirroring results from X-ray angiograms.
  • Inter-observer variation in collateral identification was noted, indicating some subjectivity in the assessment.

Takeaway

This study looked at two different dyes used in imaging to see which one helps doctors see tiny blood vessels better. The bigger dye, Gadomer, worked better than the smaller one.

Methodology

Ten rabbits underwent femoral artery ligation and were imaged using steady-state MR angiography with either Gadomer or Gd-DTPA on separate days.

Potential Biases

Observers were not blinded to the contrast agent used, which could introduce bias in the assessment of image quality.

Limitations

The study's findings may not be directly applicable to human subjects, and inter-observer variability in collateral identification was noted.

Participant Demographics

Ten male New Zealand White rabbits, approximately 3 kg in weight.

Statistical Information

P-Value

p<0.01 for femoral artery CNR comparison

Statistical Significance

p<0.05

Digital Object Identifier (DOI)

10.1371/journal.pone.0016159