Improved Malaria Case Management through the Implementation of a Health Facility-Based Sentinel Site Surveillance System in Uganda
2011

Improving Malaria Case Management in Uganda

Sample size: 424701 publication Evidence: high

Author Information

Author(s): Sserwanga Asadu, Harris Jamal C., Kigozi Ruth, Menon Manoj, Bukirwa Hasifa, Gasasira Anne, Kakeeto Stella, Kizito Fred, Quinto Ebony, Rubahika Denis, Nasr Sussann, Filler Scott, Kamya Moses R., Dorsey Grant

Primary Institution: Uganda Malaria Surveillance Project, Kampala, Uganda

Hypothesis

Can a health facility-based sentinel site surveillance system improve malaria case management?

Conclusion

The sentinel site malaria surveillance system in Uganda significantly increased the use of diagnostic testing and appropriate antimalarial prescribing practices.

Supporting Evidence

  • The proportion of patients with suspected malaria who underwent diagnostic testing increased from 39% to 97%.
  • The proportion of patients with appropriate decisions to prescribe antimalarial therapy increased from 64% to 95%.
  • The proportion of patients prescribed the recommended first-line regimen increased from 48% to 69%.

Takeaway

This study shows that by setting up a special system to check for malaria, doctors in Uganda got much better at testing patients and giving the right medicine.

Methodology

Data were collected from patients at six health facilities in Uganda, focusing on demographics, laboratory results, diagnoses, and treatments prescribed.

Potential Biases

The data collection methods were subject to bias due to varying health facility practices and potential inaccuracies in reporting.

Limitations

The study was not a controlled experiment, and improvements were made based on experience rather than a systematic approach.

Participant Demographics

Patients presenting to outpatient departments at six health facilities in Uganda.

Statistical Information

P-Value

p<0.001

Confidence Interval

95% CI 57–59%

Statistical Significance

p<0.001

Digital Object Identifier (DOI)

10.1371/journal.pone.0016316