Effect of Ageing on Orthodontic Aligners
Author Information
Author(s): Tarek M. Elshazly, Christoph Bourauel, Ahmed Ismail, Omar Ghoraba, Philippe Chavanne, Hanaa Elattar, Abdulaziz Alhotan
Primary Institution: University Hospital Bonn
Hypothesis
How does thermomechanical ageing affect the force transmission of orthodontic aligners made from different materials?
Conclusion
Multi-layer materials maintain better force application after ageing compared to single-layer materials.
Supporting Evidence
- Multi-layer materials showed lower force decay compared to single-layer materials after ageing.
- The study measured forces using pressure-sensitive films and a biomechanical setup.
- Significant force reductions were observed in all materials after 48 hours of thermomechanical ageing.
Takeaway
This study looked at how different types of clear braces change over time when they are heated and pressed. It found that some materials work better than others after being used for a while.
Methodology
The study used 50 thermoformed aligners made from five different materials, subjected them to a 48-hour ageing protocol, and measured the forces exerted on a model tooth before and after ageing.
Limitations
The study did not account for the periodontal ligament and bone, which are important for stress distribution in orthodontic appliances.