French Version of the FAAM Validated
Author Information
Author(s): Borloz Stéphane, Crevoisier Xavier, Deriaz Olivier, Ballabeni Pierluigi, Martin RobRoy L, Luthi François
Primary Institution: Département de l'appareil locomoteur, Clinique Romande de réadaptation SUVA Care, Sion, Switzerland
Hypothesis
Can the Foot and Ankle Ability Measure (FAAM) be effectively translated and validated for French-speaking patients?
Conclusion
The FAAM-F is valid and reliable for the self-assessment of physical function in French-speaking patients with a wide range of chronic foot and ankle disorders.
Supporting Evidence
- The FAAM-F showed high internal consistency with a Cronbach's Alpha of 0.97.
- Test-retest reliability was excellent with ICC values of 0.97 for ADL and 0.94 for Sports subscales.
- Convergent validity was supported by high correlation coefficients with SF-36 physical function measures.
Takeaway
This study created a French version of a questionnaire to help people with foot and ankle problems describe how they feel, and it works well.
Methodology
The FAAM-F was completed by 105 patients, and its validity and reliability were assessed through various statistical methods including correlation coefficients and internal consistency measures.
Potential Biases
The sample was not randomly drawn from the population, which may introduce selection bias.
Limitations
The study only included patients with chronic foot disorders and used a convenience sample from hospital patients.
Participant Demographics
{"average_age":50.5,"gender_distribution":{"female":64,"male":41},"diagnosis_distribution":{"degenerative":48,"traumatic":42,"congenital":6,"inflammatory":3,"tumor":1,"not_specified":5}}
Statistical Information
P-Value
p<0.0005
Confidence Interval
95%
Statistical Significance
p<0.0005
Digital Object Identifier (DOI)
Want to read the original?
Access the complete publication on the publisher's website