Robotic lower-lip mucosal graft ureteroplasty for ureteral stenosis longer than 2 cm: initial experience of thirteen patients
2024

Robotic Surgery for Ureteral Stenosis Using Lower-Lip Grafts

Sample size: 13 publication Evidence: moderate

Author Information

Author(s): Zhang Zhaolin, Zeng Xin, Wu Yuting, Wu Gengqing, He Zhihua, Zhang Guoxi, Zou Xiaofeng, Yuan Yuanhu, Xu Hui

Primary Institution: First Affiliated Hospital of Gannan Medical University

Hypothesis

Is robotic ureteroplasty with lower-lip mucosal graft feasible and effective for treating ureteral stenosis longer than 2 cm?

Conclusion

Robotic ureteroplasty with lower-lip mucosal graft is a safe and effective technique for treating ureteral stenosis.

Supporting Evidence

  • The success rate of the procedure was 92.3%, with 12 out of 13 patients showing improvement.
  • Three patients experienced postoperative complications, including fever and urinary tract infection.
  • The median stenosis length was 3.5 cm, and the mean operative time was approximately 212 minutes.

Takeaway

Doctors used a special type of surgery to fix a blocked tube in the body using a piece of skin from the lower lip, and it worked well for most patients.

Methodology

Thirteen patients with ureteral stenosis underwent robotic ureteroplasty using lower-lip mucosal grafts, with retrospective analysis of outcomes.

Potential Biases

Selection bias may be present due to the retrospective nature of the study.

Limitations

The study is retrospective, single-center, lacks a control group, and has a small sample size.

Participant Demographics

Seven male and six female patients with a mean age of 45.9 years.

Digital Object Identifier (DOI)

10.3389/fsurg.2024.1504867

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication