Antimicrobial Titanium/Silver Coatings for Implants
Author Information
Author(s): Ewald Andrea, Glückermann Susanne K, Thull Roger, Gbureck Uwe
Primary Institution: Department for Functional Materials in Medicine and Dentistry, University of Würzburg
Hypothesis
Coating titanium with a silver/titanium alloy will result in bacteria repellent properties while maintaining biocompatibility to eukaryotic cells.
Conclusion
The titanium/silver coatings provide significant antimicrobial potency without cytotoxic effects on osteoblasts and epithelial cells.
Supporting Evidence
- The coatings released sufficient silver ions when immersed in PBS.
- The coatings showed significant antimicrobial potency against Staphylococcus epidermidis and Klebsiella pneumoniae strains.
- No cytotoxic effects of the coatings on osteoblast and epithelial cells were found.
Takeaway
This study shows that adding silver to titanium coatings can help prevent infections in implants without harming human cells.
Methodology
Titanium samples were coated with titanium/silver alloys using physical vapor deposition and tested for antimicrobial properties and biocompatibility.
Statistical Information
P-Value
p<0.05
Statistical Significance
p<0.01
Digital Object Identifier (DOI)
Want to read the original?
Access the complete publication on the publisher's website