Dose-Dependent Thresholds of 10-ns Electric Pulse Induced Plasma Membrane Disruption and Cytotoxicity in Multiple Cell Lines
2011

Effects of 10-ns Electric Pulses on Cell Death and Membrane Disruption

Sample size: 5 publication 10 minutes Evidence: moderate

Author Information

Author(s): Ibey Bennett L., Roth Caleb C., Pakhomov Andrei G., Bernhard Joshua A., Wilmink Gerald J., Pakhomova Olga N.

Primary Institution: 711th Human Performance Wing, Radio Frequency Radiation Branch, Air Force Research Laboratory

Hypothesis

The study aims to measure cell survival in relation to disruptions in the plasma membrane across several commonly studied cell lines exposed to 10-ns electric pulses.

Conclusion

The study found that different cell lines have varying susceptibility to cell death and membrane disruption when exposed to 10-ns electric pulses.

Supporting Evidence

  • The LD50 for Jurkat cells was found to be 51 J/g, while for HeLa cells it was 1861 J/g.
  • PS externalization occurred at doses lower than those required for cell death in several cell lines.
  • The study suggests that cellular susceptibility to injury and death by 10-ns electric pulses is largely determined by cell physiology.

Takeaway

This study looked at how short electric pulses can hurt different types of cells, finding that some cells are more sensitive than others.

Methodology

The study used various cell lines and exposed them to 10-ns electric pulses, measuring cell death and membrane disruption through assays and flow cytometry.

Limitations

The study may not account for all variables affecting cell survival, such as the specific cellular environment and the exact mechanisms of cell death.

Participant Demographics

The study involved five different cell lines: Jurkat, U-937, GH3, CHO-K1, and HeLa.

Digital Object Identifier (DOI)

10.1371/journal.pone.0015642

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication