Monitoring Voltage-Dependent Charge Displacement of Shaker B-IR K+ Ion Channels Using Radio Frequency Interrogation
2011

Monitoring Charge Displacement in Ion Channels Using Radio Frequency

Sample size: 19 publication 10 minutes Evidence: moderate

Author Information

Author(s): Dharia Sameera, Rabbitt Richard D.

Primary Institution: Department of Bioengineering, University of Utah

Hypothesis

Can radio frequency interrogation effectively monitor voltage-dependent charge displacements in ion channels?

Conclusion

The study demonstrates that radio frequency interrogation can detect significant differences in charge displacement associated with ShB-IR K+ ion channels compared to control oocytes.

Supporting Evidence

  • ShB-IR expressing oocytes showed significantly larger changes in RF displacement currents upon membrane depolarization than control oocytes.
  • Voltage-dependent changes in RF displacement currents increased after Cu2+ addition to ShB-IR expressing oocytes.
  • The RF interrogation technique can supplement conventional membrane-biophysics studies.

Takeaway

Scientists used a special technique to see how tiny charges move in proteins that help cells send signals. They found that this movement is different when they change the voltage in the cells.

Methodology

Xenopus oocytes were injected with cRNA for ShB-IR K+ channels and subjected to two-electrode voltage clamp while monitoring RF impedance changes.

Potential Biases

Potential non-specific effects of Cu2+ on control oocytes may confound results.

Limitations

The sample size for some comparisons was small, particularly for the Cu2+ treatment group.

Participant Demographics

Xenopus laevis oocytes were used as the model organism.

Statistical Information

P-Value

0.04

Statistical Significance

p<0.05

Digital Object Identifier (DOI)

10.1371/journal.pone.0017363

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication