Whole-genome amplified DNA from stored dried blood spots is reliable in high resolution melting curve and sequencing analysis
2011

Using Dried Blood Spots for Genetic Testing

Sample size: 10 publication Evidence: high

Author Information

Author(s): Winkel Bo, Hollegaard Mads V, Olesen Morten S, Svendsen Jesper H, Haunsø Stig, Hougaard David M, Tfelt-Hansen Jacob

Primary Institution: Dept. of Cardiology, Rigshospitalet and Danish National Research Foundation Centre for Cardiac Arrhythmia (DARC), Copenhagen, Denmark

Hypothesis

Can whole genome amplified DNA from dried blood spots serve as a reliable alternative to genomic DNA from whole blood?

Conclusion

Whole genome amplified DNA from dried blood spots is reliable for high resolution melting curve analysis and sequencing.

Supporting Evidence

  • The study demonstrated 100% concordance with genotyping data obtained by the gDNA samples.
  • No false positives or negatives were found in the wgaDNA group.
  • DBS samples can serve as an alternative to whole blood in sequence analysis.

Takeaway

Scientists found that DNA from dried blood spots can be used just like DNA from regular blood for testing genes.

Methodology

DNA was extracted from whole blood and dried blood spots, then whole-genome amplified and analyzed using high resolution melting curve analysis and sequencing.

Potential Biases

Potential for unequal amplification of alleles in low concentrated samples.

Limitations

High false positive rates were observed in both wgaDNA and gDNA during melting curve analysis.

Participant Demographics

10 patients with lone atrial fibrillation, aged 19 to 28 years (mean age 22.3 years).

Statistical Information

P-Value

0.74

Statistical Significance

p = 0.74

Digital Object Identifier (DOI)

10.1186/1471-2350-12-22

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication