Stability Indicating High-Performance Liquid Chromatography Method for the Estimation of Artemether in Capsule Dosage Forms
2010

HPLC Method for Measuring Artemether in Capsules

publication Evidence: high

Author Information

Author(s): Alankar Shrivastava, R. Issarani, B. P. Nagori

Primary Institution: B.R. Nahata College of Pharmacy

Hypothesis

The study aims to develop and validate a stability indicating HPLC method for artemether.

Conclusion

The developed HPLC method is precise, accurate, and stability indicating for artemether analysis.

Supporting Evidence

  • The method showed a good linear relationship with r2 = 0.9996.
  • Limit of detection (LOD) was found to be 21.83 μg/ml.
  • The method was validated for precision, accuracy, and recovery studies.

Takeaway

Researchers created a new way to measure a medicine called artemether in capsules, making sure it works well and stays stable.

Methodology

A high-performance liquid chromatography (HPLC) method was developed and validated for artemether analysis in capsule formulations.

Digital Object Identifier (DOI)

10.4103/0975-1483.62220

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication