Corneal melting after collagen cross-linking for keratoconus: a case report
2011

Corneal Melting After Collagen Cross-Linking for Keratoconus: A Case Report

Sample size: 1 publication Evidence: low

Author Information

Author(s): Labiris Georgios, Kaloghianni Eleni, Koukoula Stavrenia, Zissimopoulos Athanassios, Kozobolis Vassilios

Primary Institution: Democritus University of Thrace, Alexandroupolis, Greece

Conclusion

The case report highlights a patient who developed corneal melting after collagen cross-linking treatment for keratoconus, leading to descemetocele and perforation despite standard postoperative care.

Supporting Evidence

  • The patient developed intense photophobia and severe corneal haze after the treatment.
  • Despite modifications to postoperative treatment, the patient's condition worsened, leading to descemetocele and perforation.
  • All laboratory tests for autoimmune and infectious diseases were negative.

Takeaway

A 23-year-old man had a serious eye problem after a treatment meant to help his vision, which ended up making it worse and required surgery.

Methodology

The patient underwent standard corneal collagen cross-linking treatment according to the Dresden protocol, followed by monitoring and modification of postoperative medications.

Limitations

The exact cause of corneal melting remains unknown, and further research is needed to address safety issues associated with the procedure.

Participant Demographics

A 23-year-old Caucasian man with keratoconus.