Measuring Bicalutamide in Tablets Using UV Spectrophotometry
Author Information
Author(s): Sancheti P. P., Vyas V. M., Shah Manali, Karekar Poonam, Pore Y. V.
Primary Institution: Government College of Pharmacy, Vidyanagar, Karad-415 124, India
Hypothesis
A simple and accurate UV spectrophotometric method can be developed for estimating bicalutamide in pharmaceutical dosage forms.
Conclusion
The developed UV spectrophotometric method for bicalutamide is simple, precise, and accurate, making it suitable for routine quality control.
Supporting Evidence
- Bicalutamide shows maximum absorbance at 272 nm.
- The method obeyed Beer's law in the concentration range of 1.5-18 μg/ml.
- The limit of detection and limit of quantification were found to be 0.1 and 0.4 μg/ml, respectively.
- The percentage recovery value was 98.63%, indicating no interference from excipients.
Takeaway
Researchers created a new way to measure a medicine called bicalutamide in tablets using light, and it works really well.
Methodology
A UV spectrophotometric method was developed and validated for the estimation of bicalutamide in tablets, including precision, accuracy, sensitivity, and linearity assessments.
Digital Object Identifier (DOI)