Biological Properties of Bioceramic Sealers on Osteoblastic Cells: A Comparative Study
2024

Biological Properties of Bioceramic Sealers on Osteoblastic Cells

publication Evidence: moderate

Author Information

Author(s): Guerra Angelita Piovezana, Gregorio Danielle, Yamamoto Gean Carlos, dos Santos Nathalia Thalitha Bernardes, Poli-Frederico Regina Celia, Maia Luciana Prado

Primary Institution: University of North Parana (UNOPAR), Londrina, ParanĂ¡, Brazil

Hypothesis

The null hypothesis is that there is no difference between the two bioceramic sealers.

Conclusion

Both bioceramic sealers exhibited comparable properties, showing cytocompatibility and promoting wound healing, but also demonstrated some degree of genotoxicity.

Supporting Evidence

  • Both bioceramic sealers showed no significant cytotoxic effects compared to the control group.
  • Both materials induced greater micronuclei formation compared to the control on days 1 and 7.
  • No significant differences in wound healing were observed among the groups.
  • Both sealers upregulated the expression of BMP1, BMP2, and ALP genes.

Takeaway

The study tested two types of dental sealers to see how they affect bone-like cells. Both sealers were safe for the cells but caused some DNA damage, so more tests are needed.

Methodology

MC3T3 osteoblast-like cells were exposed to extracts of bioceramic materials, and cytotoxicity, genotoxicity, and gene expression were evaluated using various tests.

Limitations

The study was conducted in vitro, and results may not directly translate to in vivo conditions.

Statistical Information

P-Value

p<0.05

Statistical Significance

p<0.05

Digital Object Identifier (DOI)

10.1590/0103-6440202406037