Cost Effectiveness of Computer Aided Detection in Mammography
Author Information
Author(s): Carla Guerriero, Maureen GC Gillan, John Cairns, Matthew G Wallis, Fiona J Gilbert
Primary Institution: London School of Hygiene and Tropical Medicine
Hypothesis
Is single reading with computer aided detection (CAD) more cost-effective than double reading for detecting cancer in screening mammograms?
Conclusion
Single reading with CAD is unlikely to be a cost-effective alternative to double reading for mammography screening in the UK.
Supporting Evidence
- CAD is cost increasing for all sizes of screening unit.
- The introduction of CAD would produce an additional cost of £227 and £253 per 1,000 women screened in high and average volume units respectively.
- In low volume screening units, the high cost of purchasing the equipment results in an additional cost of £590 per 1,000 women screened.
- Sensitivity analyses showed that reading time and reader qualification significantly affect cost-effectiveness.
- The study provides updated estimates of CAD costs in a full-field digital system.
Takeaway
Using a computer to help read mammograms costs more than having two people read them, so it's not a good idea right now.
Methodology
The study analyzed cost-effectiveness based on data from the CADET II trial, comparing single reading with CAD to double reading over a seven-year period.
Potential Biases
The study may be biased due to the assumptions made about CAD performance and the costs associated with different diagnostic procedures.
Limitations
The study assumes CAD effectiveness is the same with digital mammography as with film, and does not account for variations in assessment costs across regions.
Participant Demographics
Women aged 50-70 undergoing routine screening in England.