Estimating Phosphorus in Coal and Ash Using FTIR Spectroscopy
Author Information
Author(s): Vinod Arya, Prasad Anup Krishna, Mishra Sameeksha, Purkait Bitan, Mukherjee Shailayee, Shukla Anubhav, Desinayak Nirasindhu, Sarkar Bhabesh Chandra, Varma Atul Kumar
Primary Institution: Indian Institute of Technology (Indian School of Mines), Dhanbad, Jharkhand, India
Hypothesis
Can FTIR spectroscopy combined with machine learning models accurately quantify phosphorus content in coal and coal ash?
Conclusion
The study found that FTIR combined with a multi-model approach is a reliable tool for rapid measurement of phosphorus in coal and coal ash.
Supporting Evidence
- FTIR spectroscopy can detect low levels of phosphorus in coal and coal ash.
- The multi-model estimation technique showed high correlation with XRF measured phosphorus content.
- Statistical tests indicated no significant difference between measured and predicted phosphorus values.
- PLR, PLSR, and RF methods were more robust than SVR in estimating phosphorus content.
- The proposed method is simpler and cost-effective compared to traditional methods like XRF.
Takeaway
This study shows a new way to quickly check how much phosphorus is in coal and its ash, which is important for making energy and protecting the environment.
Methodology
The study used FTIR spectroscopy and machine learning models (PLR, PLSR, RF, SVR) to analyze phosphorus content in coal and ash samples.
Potential Biases
Potential biases may arise from sample preparation and the specific conditions under which FTIR measurements were taken.
Limitations
The study's findings may not be generalizable to all coal types or other natural samples without further validation.
Statistical Information
P-Value
p<0.01
Statistical Significance
p<0.01
Digital Object Identifier (DOI)