Hematological Changes in Platelet Apheresis Donors
Author Information
Author(s): Muacevic Alexander, Adler John R, Sharma Anjali, Arakeri Satish, Kanungo Rahul, Pagi Sajal
Primary Institution: Shri B M Patil Medical College Hospital & Research Centre, BLDE (Deemed to be University), Vijayapura, IND
Hypothesis
This observational study aims to evaluate hematological changes in donors before and after platelet donation via apheresis.
Conclusion
Automated cell separators have significantly improved SDP quality and collection efficiency.
Supporting Evidence
- The mean fall in platelet count after donation was 50,833/mm3.
- The overall mean fall in hematocrit was 1.16%, with a range of 0.5-2%.
- Donors with a platelet yield of 3.0x1011 had an average hematocrit reduction of 1.13%.
- Donors with a yield of 3.5x1011 had a higher reduction of 1.56%.
- The study emphasizes the importance of personalizing collection parameters.
Takeaway
This study shows that donating platelets can lower your blood's platelet count a bit, but it's safe and helps patients who need blood.
Methodology
This was a pilot study involving 30 plateletpheresis procedures where hematological parameters were measured before and after donation.
Limitations
The small sample size of 30 male donors limits the generalizability of findings.
Participant Demographics
All donors were male, aged 18-45 years, with a mean weight of 73.53 kg and average height of 170.7 cm.