Quantitative correlation of breast tissue parameters using magnetic resonance and X-ray mammography
1996

Breast Tissue Analysis Using MRI and Mammography

Sample size: 42 publication Evidence: moderate

Author Information

Author(s): SJ Graham, MJ Bronskill, JW Byng, MJ Yaffe, NF Boyd

Primary Institution: University of Toronto, Sunnybrook Health Science Centre

Hypothesis

The study investigates the correlation between breast tissue parameters measured by MRI and X-ray mammography.

Conclusion

The study found strong correlations between MRI parameters of breast tissue and mammographic density, suggesting MRI could be useful for assessing breast cancer risk.

Supporting Evidence

  • Relative water content showed a strong positive correlation with per cent density (rp=0.79, P<0.0001).
  • Mean T2 value showed a strong negative correlation with per cent density (rp= -0.61, P<0.0001).
  • The MR and X-ray parameters were associated with sociodemographic and anthropometric risk factors for breast cancer (P<0.05).

Takeaway

This study looked at how different types of breast tissue can be measured using MRI and X-ray, and found that these measurements can help understand breast cancer risk.

Methodology

The study involved 42 asymptomatic women aged 40-50, using MRI to measure water content and T2 relaxation time, and X-ray mammography to determine breast density.

Potential Biases

Potential bias in subject selection may affect the results.

Limitations

The small sample size and potential bias in subject selection limit the generalizability of the findings.

Participant Demographics

All participants were female, aged 40 to 50, with no history of breast cancer.

Statistical Information

P-Value

P<0.0001

Confidence Interval

(0.64, 0.88)

Statistical Significance

p<0.05