Initial Experience With Senhance-Assisted Laparoscopic Partial Cystectomy Using the Double Bipolar Method With 3 mm Bipolar Instruments
2024

Using Senhance Robot for Bladder Surgery

Sample size: 1 publication Evidence: low

Author Information

Author(s): Muacevic Alexander, Adler John R, Kawabata Junya, Kaneko Go, Shirotake Suguru, Matsushita Suguru, Homma Taku, Oyama Masafumi, Koyama Isamu

Primary Institution: Saitama Medical University International Medical Center

Hypothesis

The double bipolar method (DBM) can enhance the precision and outcomes of laparoscopic partial cystectomy using the Senhance robotic system.

Conclusion

The DBM technique with the Senhance system allows for precise and bloodless bladder wall resection.

Supporting Evidence

  • The Senhance robotic system allows for precise and cost-effective procedures.
  • The double bipolar method enables simultaneous use of bipolar instruments for better control.
  • The patient had an uncomplicated recovery and was discharged on the eighth postoperative day.

Takeaway

Doctors used a special robot to help remove a tumor from a patient's bladder without causing any bleeding, making the surgery easier and safer.

Methodology

A 62-year-old female underwent a Senhance-assisted laparoscopic partial cystectomy using the double bipolar method with 3 mm instruments.

Limitations

This is a single case report, limiting the generalizability of the findings.

Participant Demographics

One 62-year-old female patient with a body mass index of 40.8 kg/m2.

Digital Object Identifier (DOI)

10.7759/cureus.74074

Want to read the original?

Access the complete publication on the publisher's website

View Original Publication