The Roman Bridge: a double pulley – suture bridges technique for rotator cuff repair
Author Information
Author(s): Franceschi Francesco, Longo Giuseppe Umile, Ruzzini Laura, Rizzello Giacomo, Maffulli Nicola, Denaro Vincenzo
Primary Institution: Campus Biomedico University
Hypothesis
The Roman Bridge technique optimizes rotator cuff tendon-footprint contact area and mean pressure.
Conclusion
The Roman Bridge technique maximizes the strength of the repair and prevents synovial fluid from penetrating the healing area of tendon and bone.
Supporting Evidence
- The double pulley technique provides secure fixation in the medial aspect of the footprint.
- Suture bridges improve pressurized contact area and mean footprint pressure.
- The technique allows sharing the load between fixation points.
- It maximizes the strength of the repair.
- The technique is more expensive than single row suture anchor repairs.
Takeaway
This study describes a new way to fix a shoulder tendon that helps it heal better and stay in place.
Methodology
An arthroscopic rotator cuff repair technique using suture bridges to optimize tendon-footprint contact area.
Limitations
The technique may be more expensive than single row suture anchor repairs and could potentially lead to one of the medial anchors pulling out.
Participant Demographics
Ideal for patients with medium U-shaped rotator cuff tears; not indicated for large or massive tears.
Digital Object Identifier (DOI)
Want to read the original?
Access the complete publication on the publisher's website