The Roman Bridge: a "double pulley – suture bridges" technique for rotator cuff repair
2007

The Roman Bridge: a double pulley – suture bridges technique for rotator cuff repair

publication Evidence: moderate

Author Information

Author(s): Franceschi Francesco, Longo Giuseppe Umile, Ruzzini Laura, Rizzello Giacomo, Maffulli Nicola, Denaro Vincenzo

Primary Institution: Campus Biomedico University

Hypothesis

The Roman Bridge technique optimizes rotator cuff tendon-footprint contact area and mean pressure.

Conclusion

The Roman Bridge technique maximizes the strength of the repair and prevents synovial fluid from penetrating the healing area of tendon and bone.

Supporting Evidence

  • The double pulley technique provides secure fixation in the medial aspect of the footprint.
  • Suture bridges improve pressurized contact area and mean footprint pressure.
  • The technique allows sharing the load between fixation points.
  • It maximizes the strength of the repair.
  • The technique is more expensive than single row suture anchor repairs.

Takeaway

This study describes a new way to fix a shoulder tendon that helps it heal better and stay in place.

Methodology

An arthroscopic rotator cuff repair technique using suture bridges to optimize tendon-footprint contact area.

Limitations

The technique may be more expensive than single row suture anchor repairs and could potentially lead to one of the medial anchors pulling out.

Participant Demographics

Ideal for patients with medium U-shaped rotator cuff tears; not indicated for large or massive tears.

Digital Object Identifier (DOI)

10.1186/1471-2474-8-123