Comparison and agreement between venous and arterial gas analysis in cardiopulmonary patients in Kashmir valley of the Indian subcontinent
2011

Comparing Blood Gas Analysis Methods in Cardiopulmonary Patients

Sample size: 100 publication 10 minutes Evidence: moderate

Author Information

Author(s): Parvaiz A. Koul, Umar Hafiz Wani, Abdul Ahad Eachkoti, Rafiqa Jan, A. Shah, Sanaullah Masoodi, Zarka Qadri, Syed Mudassir Ahmad, Muneer Ahmad Asrar

Primary Institution: Sher-i-Kashmir Institute of Medical Sciences

Hypothesis

Can venous blood gas analysis be used as a reliable alternative to arterial blood gas analysis in cardiopulmonary patients?

Conclusion

Using peripheral venous blood gas assessment along with finger pulse oximetry can reduce the need for painful arterial punctures in patients requiring blood gas analysis.

Supporting Evidence

  • Venous measurements of pH, pCO2, pO2, and bicarbonate were highly correlated with arterial measurements.
  • Bland Altman plots showed a high degree of agreement between arterial and venous measurements.
  • Significant correlations were found for pH, pCO2, and bicarbonate levels.
  • SaO2 and SpO2 showed excellent agreement with clinically acceptable differences.

Takeaway

Doctors can use blood from veins instead of arteries to check how well patients' lungs are working, which is less painful.

Methodology

100 patients requiring ABG analysis had both arterial and venous blood samples taken within 5 minutes, and results were analyzed for correlation and agreement.

Potential Biases

Potential bias due to the study being conducted in a specific geographic location with unique patient demographics.

Limitations

The study was conducted in a single center and may not be generalizable to all populations.

Participant Demographics

63 males and 37 females, mean age 44 ± 19.63 years, with various cardiopulmonary disorders.

Statistical Information

P-Value

<0.001

Confidence Interval

95% CI for correlation coefficients provided in the results.

Statistical Significance

p<0.05

Digital Object Identifier (DOI)

10.4103/1817-1737.74274