Estimating Minimum Foot Clearance with a Sensor and 3D Foot Scan
Author Information
Author(s): Katherine Heidi Fehr, Jennifer Nicole Bartloff, Yisen Wang, Scott Hetzel, Peter G. Adamczyk
Primary Institution: University of Wisconsin-Madison
Hypothesis
Can a single foot-mounted inertial sensor combined with a personalized foot geometry scan accurately estimate minimum foot clearance during gait?
Conclusion
The proposed method accurately estimates minimum foot clearance and shows significant differences in foot clearance under various interventions.
Supporting Evidence
- The method showed a bias of less than 0.05 mm compared to motion capture.
- Minimum foot clearance decreased significantly over time in the no-intervention case.
- Using a functional electrical stimulation device also resulted in significant decreases in foot clearance.
- The AFO condition showed a borderline significant increase in clearance.
Takeaway
This study shows a new way to measure how high your foot is off the ground when you walk, which can help prevent trips and falls.
Methodology
The study used a foot-mounted inertial sensor and a 3D scan of the foot to reconstruct the foot's movement during walking and estimate minimum foot clearance.
Potential Biases
Potential misalignment of the IMU during data collection could introduce bias in the measurements.
Limitations
The method assumes the foot is a rigid body, which may lead to inaccuracies during stance phase.
Participant Demographics
Participants had foot-drop due to multiple sclerosis.
Statistical Information
P-Value
p<0.001
Confidence Interval
−8.18 to +8.09 mm
Statistical Significance
p<0.001
Digital Object Identifier (DOI)
Want to read the original?
Access the complete publication on the publisher's website